Part Number Hot Search : 
2SC16 BGY88 74F2645 MXD1816 74AC10 MAX150 5261B 5ETTTS
Product Description
Full Text Search
 

To Download SGT961360 Datasheet File

  If you can't view the Datasheet, Please click here to try to view without PDF Reader .  
 
 


  Datasheet File OCR Text:
 S/TRI/SGT961360/B/7/05/2002
page 1 / 2 F/GB
Relais Statique Triphase Three Phase Solid State Relays
* Sortie AC pour charges resistives. * Commande 8,5-30 Vdc et LED. * Possibilite de protection IP10 en option:Capot 1K199 000. * AC output for resistive loads. * 8,5-30 VDC control voltage with LED. * Protection IP10 optional (1K199 000).
SGT961360
24 to 600 VAC - 12 ARMS
Dimensions / Dimensions:
Application typique /Typical application:
R S T R S T R S T
Circuit equivalent/Equivalent circuit :
1L1
39,5
A1 +
Adaptateur / Adapter
2T1
82,7 19 19
LED
Resistive or inductive load
3L2
Adaptateur / Adapter
4T2 5L3
M
4,4
A2 -
1L1
3L2
5L3
58,4
73,5
23
40
A2 -
Adaptateur / Adapter
6T3
A1+ 2T1 4T2 6T3
91 100
Caracteristiques de commande (a 20C) / Control characteristics (at 20C) Parametre / Parameter Tension de commande / Control voltage Courant de commande / Control current (@ Uc ) Tension de relachement/Release voltage Resistance interne / Input internal resistor fig.1 Tension inverse / Reverse voltage Symbol Uc Ic Uc off Rc Urv Min 8,5 10 4 DC Nom 24 35 620 30 Max 30 45 Unit V mA V V VRMS VRMS V
fig. 1 :Caracteristique d'entree / Control characteristic
50 40 30 20 10 0 0 2 4 6 8 10 12 14 16 18 20 22 24 26 28 30
Caracteristiques d'entree-sortie (a 20C) / Input-output characteristics (at 20C) Isolement entree-sortie/Input-output isolation @500m Ui 4000 Isolement sortie-semelle/Output-case isolation @500m Ui 2500 Tension assignee isolement/ Rated impulse voltage Uimp 4000 Caracteristiques generales / General characteristics Parametre / Parameter Poids/Weight Plage de temperature de stockage / Storage temperature range Plage de temperature de fonctionnement/Operating temperature range
Ic(mA)
Uc(V)
Conditions
Symbol
Typ. 370 -40 / +100 -40 / +100
Unit g C C
Proud to serve you
All technical caracteristics are subject to change without previous notice. Caracteristiques sujettes a modifications sans preavis.
celduc
r e l a i
s
S/TRI/SGT961360/B/7/05/2002
Caracteristiques de sortie(a 20C) / Output characteristics (at 20C) Parametre / Parameter Tension de charge / Load voltage Plage tension de fonctionnement / Operating range Tension crete / Peak voltage Niveau de synchonisation / Synchronizing level Tension d'amorcage / Latching voltage Courant nominal AC-51/ AC-51 nominal current Courant de surcharge non repetitif /Non repetitive overload current Chute tension directe crete/ On state voltage drop Courant de fuite etat bloque/ Off state leakage current Courant de charge minimum / Minimum load current Temps de fermeture/ Turn on time Temps d'ouverture/ Turn off time Plage de frequence / Operating frequency range dv/dt etat bloque / Off state dv/dt dI/dt maximum non repetitif/ Maximum di/dt non repetitive I2t (<10ms) EMC Test d'immunite conduite / Conducted immunity level EMC Test d'immunite conduite / Conducted immunity level Conformite / Conformity Caracteristiques thermiques / thermal curves :
60
page 2 / 2 F/GB
Conditions Symbol Ue Uemin-max Up Usync Ua Ie AC-51 Itsm Vd Ilk Ie min ton max toff max f dv/dt di/dt I2t Typ. 400 24-600 1200 24 10 12 Unit V rms V rms V V V A rms
Ie nom ( see Fig. 2 ) tp=10ms (Fig. 3) @ Ie nom @Ue, 50Hz Uc nom DC ,f=50Hz Uc nom DC ,f=50Hz
IEC 1000-4-4 (burst) IEC 1000-4-5(schocks) EN60947-4-x
120 A 1,4 V 1 mA 5 mA 10 ms 10 ms 10-440 Hz 500 V/s 50 A/s 72 A2s 2kV criterion B 2kV crit.A with external VDR
0,95K/W
50
1,2K/W
Total wasted power (W)
40 Full on-state 30
3K/W
20
without heatsink
10
Fig.3 Courbes de surcharge de courant / Overload current curves
0 0 2 4 6 8 10 12 0 10 20 30 40 50 60 70 80 90 100 Ambient temperature (C) RMS load current (A)
Surge current Itsm (Apeak) = f(t) for models with itsm =120A 150 Itsm (Apeak)
No repetitive Itsm (Apeak)=f(t) without voltage reapplied
100
1 -Itsm non repetitif sans tension reappliquee est donne pour la determination des protections. No repetitive Itsm is given without voltage reapplied for the determination of the protection. 2 -Itsm repetitif est donne pour des surcharges de courant (Tj initiale=70C). La repetition de ces surcharges de courant diminue la duree de vie du Relais. Repetitive Itsm is given for inrush current with initial Tj = 70C. The repetition of the surge current decrease the lifetime SSR's .
50
Repetitive Itsm (Apeak)=f(t) with voltage reapplied for initial Tj =70C
0 0,01
0,1 t(s)
1
10
Precautions : * Les relais a semiconducteurs ne procurent pas d'isolation galvanique entre le reseau et la charge.
Cautions : * Semiconductor relays don't provide any galvanic insulation between the load and the mains.
celduc
r e l a i s
www.celduc.com
Rue Ampere B.P. 4 42290 SORBIERS - FRANCE E-Mail : celduc-relais@celduc.com Fax +33 (0) 4 77 53 85 51 Service Commercial France Tel. : +33 (0) 4 77 53 90 20 Sales Dept.For Europe Tel. : +33 (0) 4 77 53 90 21 Sales Dept. Asia : Tel. +33 (0) 4 77 53 90 19


▲Up To Search▲   

 